Guide · Spray foam basics16 min read

What is spray foam insulation? A guide for commercial buildings.

Polyurethane insulation sprayed as a liquid that sets into a continuous layer bonded to the roof, wall or soffit. Closed-cell and open-cell do different jobs, so tell us what you need the building to do.

The short answer

What is spray foam insulation? It is polyurethane insulation sprayed as a liquid that expands and sets into a continuous layer bonded to the roof, wall or soffit. On commercial buildings, closed-cell foam is rigid, seals laps and fixings and, correctly specified, stops condensation on cold metal sheets; open-cell foam is softer and vapour-open, used for thermal and acoustic insulation in suitable breathable build-ups.

Closed-cellrigid and vapour-resistant, bonded to cold metal
Open-cellsofter and vapour-open, used for thermal and acoustic insulation in suitable breathable build-ups
Roofer firstif the roof leaks, before any insulation

If you're looking up at a cold warehouse roof, the question is what you need the insulation to do. Stop drips? Keep heat in? Quiet the rain? A profiled sheet, a concrete soffit and a timber deck need different answers.

HOLVEM is a commercial building-performance company. We establish what is happening in the building first, then specify what should change beneath the surface. Our own teams survey, specify and install nationwide across England and Wales, with coatings where the work needs them.

So let's start with the material, then work through the checks for your building. If you're ready to discuss a job, see our commercial spray foam insulation service.

01What it is and how it goes on

What it is and how it is applied

From roof to quote, in order

  1. 01Show us the roofPhotographs, drawings and the layers already there.
  2. 02Tell us the problemA wet underside, a cold work area, rain drumming or a U-value target.
  3. 03We check and calculateThe construction, the layers and the depth.
  4. 04Agree the resultA quote for the complete work, with the finish.

Two liquid components meet as they are sprayed, expand on the surface and set into polyurethane insulation. Because the layer forms there, it follows the roof profile instead of leaving you to fit separate boards around every corrugation.

That is useful on a curved steel arch or an irregular concrete soffit. We can follow the shape and seal the agreed details. In a hybrid roof, the foam works alongside other insulation, membranes and linings, each with its own job.

But the surface has to be ready. We check old finishes, dirt, corrosion and damage before setting the preparation. If the roof leaks, a roofer fixes it first. Spraying underneath a live leak only hides the problem.

Spraying underneath a live leak only hides the problem.

Your quote should say where the layer starts and stops, how thick it will be and what finish it needs. Rooflights stay clear; services that need future access are identified before we spray.

Then we plan the floor below. You may need to move stock or vehicles, or release a bay while we protect machinery. We'll agree access, ventilation, separation and re-entry with you before the team arrives.

Insulation, an air seal and the complete building

Insulation slows heat transfer through the treated roof, wall or soffit. A continuous layer also seals the air paths it covers. Open doors and untreated wall junctions still matter, so tell us where you feel the draughts as well as where you see the water.

Tell us what you need the building to do. A wet underside, a cold work area, rain drumming on the roof and a written U-value target are different starting points. You can bring more than one problem; we'll give each one a place in the proposal.

Afterwards, keep the specification, thickness checks, coverage photographs, calculations and finish records with your building file. When someone asks what went on the roof, you have the answer.

The sequence is simple: show us the roof, tell us the problem and agree the result. We check the construction, calculate the layers and quote the complete work. You can see what you are buying.

02Closed-cell and open-cell

Closed-cell and open-cell compared

Closed-cell foam is rigid and vapour-resistant. Open-cell is softer and vapour-open, with an acoustic role in suitable constructions. They are not interchangeable roof treatments.

QuestionClosed-cellOpen-cell
General characterRigid, bonded and vapour-resistantSofter, vapour-open and sound-absorbing
Appropriate commercial rolesSuitable cold metal, retained roof surfaces and concrete soffits; assessed hybrid constructionsSuitable acoustic and vapour-open assemblies, including specified roof build-ups
What decides suitability?Substrate, moisture design, objective and complete constructionDrying path, substrate, moisture design, acoustic objective and complete construction
Directly on a cold metal sheet?The specified foam type for the suitable direct-bonded treatmentNot a substitute for closed-cell directly on that cold sheet
Does its name check the roof's U-value?No; calculate the complete elementNo; calculate the complete element
Does its name establish fire compliance?No; tested assembly and fire strategy decideNo; tested assembly and fire strategy decide

For open cell vs closed cell spray foam, ask where moisture can go and what each layer needs to do. On a cold steel sheet, we need a rigid, vapour-resistant layer bonded to the metal. In an acoustic build, softer open-cell foam can play a different role.

Sometimes both belong in one roof. That is a designed hybrid: each material does a job, and the layers are checked together. It isn't a matter of spraying whichever foam is available.

Closed-cell system data and open-cell system data explain HOLVEM's material roles. Use the declared data for the selected system and assess its behaviour with the layers already in the building.

What the project examples show

At The Alban Arena in St Albans, we used open-cell and closed-cell in the roof of a working venue. Across more than 29 schools in Hampshire and Berkshire, we applied open-cell to single-storey flat roofs. Those are practical examples of the different roles.

Each new building gets its own specification.

A sample tells you how the material feels. Your roof drawings tell us where it belongs. We need both the existing layers and the required finish to design the new build-up.

03On a commercial roof

What it does on a commercial roof

A profiled or curved roof has plenty of awkward corners for a fitted insulation system. A sprayed layer follows those contours and bonds to the surface. That is why it works beneath corrugated sheets, curved arches and irregular soffits.

Foam thickness is only part of the thermal answer. The sheet, old insulation, cavities and steel bridges all count, so we calculate the whole roof. The foam's declared conductivity feeds that calculation; it isn't the roof's U-value.

The same care applies at junctions and penetrations. Sealing the air path around steel helps with draughts, while the steel itself still conducts heat. Your calculation needs to include both.

A · Across the profile

Section across a profiled metal roof sheet: a closed-cell layer bonded beneath the sheet follows the ribs and pans, and covers a side lap with its fixing.OUTSIDEINSIDE123

B · Along the slope, at a purlin

Section along the slope at a purlin: the fixing passes through the sheet into the steel purlin; the closed-cell layer is carried around the top of the purlin, and the steel below still conducts heat.OUTSIDEINSIDE45
  1. Profiled metal sheetRetained in place; the sprayed layer follows its contours.
  2. Closed-cell layerRigid and vapour-resistant, bonded to the metal. The survey sets the depth.
  3. LapClosed-cell foam seals laps and fixings.
  4. FixingThrough the sheet into the purlin, sealed by the bonded layer.
  5. Steel purlinSealing the air path around steel helps with draughts, while the steel itself still conducts heat. The calculation includes both.

Heat conducted through the steel

Illustrative section, not a job photograph: closed-cell foam bonded beneath a profiled metal roof. The survey sets the depth for your roof.

Condensation on a cold metal roof

Correctly diagnosed and specified, closed-cell spray foam stops roof condensation. Zero call-backs for condensation. The depth is typically 25 mm or 50 mm closed-cell, depending on the roof make-up, confirmed before we spray. We use a condensation risk analysis where needed. Existing leaks go to a roofer first.

At TJW Grab Hire in Bournemouth, about 505 m² of box-profile steel roof in good condition ran with condensation onto the vehicles and equipment beneath it. We sprayed 50 mm closed-cell to the underside. The customer reported that the condensation was eliminated.

Backed by our 25 year HOLVEM workmanship warranty, plus the manufacturer's 25 year product warranty issued directly to you.

The survey sets the depth for your roof. Read TJW Grab Hire.

Heat loss and rain noise need their own answers

If your designer has set a U-value, send it with the drawings. We'll calculate the complete roof, wall or soffit against that target. A layer chosen to stop condensation can be shallower than one needed to meet a thermal requirement.

Rain noise is another job. Open-cell has a sound-absorbing role in suitable builds; at Black Hangar Studios, the studio reported that drumming and resonance from rain and wind were virtually eliminated.

Read thickness and objective for the depth decision and rain noise and acoustics for that separate building problem.

Project recordRoof underside
Roof underside sprayed in continuous passesReal installation footage, from below.

04Fire and coatings

Fire performance and coatings

For fire performance, ask which build-up was tested. The substrate, foam depth and coating or lining belong with the result. We'll check that evidence against your project's fire strategy.

The manufacturer's fire evidence includes an uncoated Class 1 surface-spread-of-flame result to BS 476-7 at 45 to 50 mm on 9 mm plasterboard. Its coated B-s2,d0 assembly was tested at 35 to 40 mm on 9 mm plasterboard, with an intumescent coating at 0.7 mm wet film thickness. These are results for those tested assemblies.

Keep those two tests separate: Class 1 is a British surface-spread result; B-s2,d0 is the coated assembly's Euroclass. Your fire strategy decides which construction and finish you need.

Ask what coating or lining is included, how it is applied and what evidence you get at handover. An exposed soffit and a layer behind a ceiling can need different finishes. Your quote should make that clear.

Read fire performance and coatings. HOLVEM is an accredited installer for the manufacturer of the spray foam systems we apply.

05The wrong choice

Where it is the wrong choice

Sometimes the survey points to another trade first. That's useful: you want to know about the failed sheet or wet deck before you pay to cover it.

Building findingWhat happens before an insulation proposal
Active roof leakA roofer establishes and repairs the water entry
Unsound roof or supporting structureA roofing or structural professional assesses it and sets the work needed
Surface unsuitable for adhesionWe set the preparation or a different construction; we never cover the defect
Timber build-up with an uncertain moisture routeAssess retained layers, vapour control and drying before choosing insulation
Fire strategy requiring a different assemblySelect a construction with applicable evidence and the required finish
Working area can't be controlledAgree suitable access and site plan before installation
Roof already due for replacementCompare the designed new assembly with a separate internal retrofit work

At The Regis School in Bognor Regis, one of two steel containers had a live leak, so we did not spray it. Insulating from inside never repairs an active leak.

Asbestos-containing or suspected materials need the dutyholder, a competent asbestos surveyor and HSE guidance involved in the assessment. HOLVEM never removes asbestos sheets. If the roof is safe to keep, we encapsulate it; if not, removal is a job for asbestos removal professionals, licensed where HSE requires it.

Timber roofs need their own moisture decision

With timber, we need to know what is above and below the deck: weather covering, old insulation, membranes, cavities and lining. Those layers decide how moisture moves and how the timber can dry.

So we check the proposed roof before choosing the foam. Ventilation and access for future inspection stay in the design; they aren't details to sort out after the timber is covered.

For a home loft, use the RICS consumer guide and an independent adviser who can inspect that dwelling.

06Compare the complete work

Costs: compare the complete work

Our cost guide gives HOLVEM's published prices. Its installed foam-only ranges are £16 to £25/m² + VAT at 25 mm and £22 to £35/m² + VAT at 50 mm. Deeper applications and coated systems are priced for the project.

Your quote should name the area, depth, preparation, access, protection, finish and programme. That way a foam-only price is easy to distinguish from a complete coated system.

Now compare the finished work. A board system may need supports and a lining; sprayed foam may need high-level access and a fire coating. Ask each contractor to show what is included.

Tell us about working hours and fixed machinery at the start. Clearing one bay for a continuous run is different from short access windows around live plant. We'll price the plan your building actually needs.

Compare the installed methods

MethodTypical installed cost per m²What you are buying
Closed-cell spray foam, 25 mm£16 to £25 + VATFoam only on a sound, prepared surface; the roof stays in place
Closed-cell spray foam, 50 mm£22 to £35 + VATFoam only, with depth confirmed for your roof at survey
PIR or rigid boards£30 to £50 installedA fitted board system; compare supports, joints and finish
Mineral wool and liner£20 to £30 installedInsulation with its supporting liner and vapour-control details
Roof overcladding£60 to £90A new weather-facing roof system over the retained roof
Insulated panels or replacement£100 to £160 + VATA new insulated roof, with removal and access checked in the quote

These are the method figures in our cost guide, not a quote for your building. The guide does not state a VAT basis for the board, mineral-wool and overcladding rows, so ask the contractor to confirm it. Added coatings and external foam systems are priced per project. Compare what is included before you compare the totals.

07Commercial projects

Commercial projects: different reasons to specify

Black Hangar Studios, Alton

A 4000 m² hangar under a corrugated asbestos-cement roof, insulated from below with closed-cell and open-cell foam, with nothing cut or removed. The studio reported that the drumming and resonance from rain and wind were virtually eliminated. Read Black Hangar Studios.

The Alban Arena, St Albans

Read The Alban Arena: 100 mm of open-cell and 25 mm of closed-cell in the roof of a working venue.

If your building stays in use, the programme belongs beside the technical design. We agree which areas you release, what needs protection and when work can take place.

School flat roofs

Across more than 29 schools in Hampshire and Berkshire, we applied open-cell foam to single-storey flat roofs. Read the schools programme.

TJW Grab Hire, Bournemouth

TJW's sound steel roof was running with condensation, not leaking, so it took 50 mm closed-cell to the underside.

Steel and metal roofs are the core of our work. Our own teams survey, specify and install from four depots: Weybridge, Bedford, Manchester and Exeter.

08Where to start

Three questions point to the first step.

Answer the three below. The result names the first step; the survey confirms the material, depth and finish.

Spray foam insulation

Your building, in three answers.

1What do you need the insulation to do?
2What is the roof or surface?
3Does water come through when it rains?

Request a survey

Ask for a survey. We ring to arrange it around your floor.

Where the building is and how to reach you. A specialist rings to agree a time that suits the shift pattern; the survey is free and carries no obligation.

Enter your name.

Enter a UK postcode.

Enter an email address or a telephone number.

Enter an email address or a telephone number.

Before 3pm on a working day, contacted the same day.

09HOLVEM

Why choose HOLVEM for commercial spray foam insulation?

You don't have to choose a foam before you call us. Tell us what is happening beneath your roof and we'll recommend the material, depth and finish that do the job. Our own teams take you from survey to installation, nationwide across England and Wales from four depots.

That experience covers over 500 installs. At TJW Grab Hire, we sprayed about 505 m² of sound steel roof with 50 mm closed-cell; the customer reported the condensation eliminated. At The Alban Arena, open-cell and closed-cell each had a role in a working venue.

We use certified spray foam systems, which we apply as an accredited installer for the manufacturer, and give you the written specification, roof calculations and QA evidence pack at handover. So you have the answers when a surveyor or insurer asks about the work.

Backed by our 25 year HOLVEM workmanship warranty, plus the manufacturer's 25 year product warranty issued directly to you.

10Questions, answered

Questions about spray foam insulation

What is spray foam insulation made of?

It is polyurethane insulation. Two liquid components meet during spraying, expand on your roof, wall or soffit, and set into the chosen foam type. We select the system for the surface and the job it needs to do.

What is the difference between open-cell and closed-cell?

Closed-cell is rigid and vapour-resistant; open-cell is softer and vapour-open, with an acoustic role in suitable builds. We choose the material from your roof layers, moisture path and required result.

Is spray foam suitable for metal roofs?

Yes. We use closed-cell on sound profiled and curved metal roofs, after checking for leaks, preparation and the required finish. The survey sets the depth.

When should you not use spray foam?

When the surface, moisture path, fire strategy or working area can't support the proposed treatment. We explain what needs fixing first or recommend another construction.

Is spray foam fire-rated?

The uncoated foam has a Class 1 surface-spread-of-flame result to BS 476-7 at 45 to 50 mm on 9 mm plasterboard. The coated assembly, 35 to 40 mm on 9 mm plasterboard with an intumescent coating, is classified B-s2,d0. Each result applies only to its tested build-up; your fire strategy decides which you need.

How long does it last?

Once cured, closed-cell foam stays bonded to the roof as one continuous layer. How long it performs depends on a sound, dry roof and the right specification, which is why leaks go to a roofer first. Backed by our 25 year HOLVEM workmanship warranty, plus the manufacturer's 25 year product warranty issued directly to you.

Start a project brief. Tell us about the building and what you want to change.

11In five lines

Spray foam insulation, in five lines.

  1. Spray foam is polyurethane insulation sprayed as a liquid that expands and sets into a continuous layer bonded to the roof, wall or soffit.
  2. Closed-cell is rigid and vapour-resistant; open-cell is softer and vapour-open, with an acoustic role in suitable builds. They are not interchangeable roof treatments.
  3. Correctly diagnosed and specified, closed-cell spray foam stops roof condensation. Zero call-backs for condensation. The survey sets the depth for your roof.
  4. We calculate the complete roof for a U-value, and the tested assembly and your fire strategy decide the finish.
  5. If the roof leaks, a roofer fixes it first. Then compare the complete work: foam only is £16 to £25/m² + VAT at 25 mm and £22 to £35/m² + VAT at 50 mm.

The next step

Start a project brief, or send photographs.

Start a project brief and tell us about the building and what you want to change, or send photographs of the underside with any drawings.

Back to the three questions

Where this guide leads

The pages that go deeper on your building, your roof and the price.

Your next step

Your building.
Your brief.
A specialist.

If you already know the thickness or U-value you need, we price to it and confirm it is right; if not, we work it out with you. Tell us what you know about the building and the problem; if something is uncertain, say so. Someone who does this every day reads it and comes back to you.