Retail units: a dry, warm shop floor, with trading continuing.

Retail sheds, high street units and the soffits above them. Condensation, cold floors and energy bills, treated from inside out of hours, with the doors open again in the morning.

Retail sheds, units and centre soffitsOut of hours, trading continuesFrom £16/m² + VAT at 25 mm

Same-day estimator

About a minute · no obligation

Step 1 of 4: your building.

Which building is it?

This page's building is pre-selected. Change it if yours is different.

Takes about 30 seconds. No contact details yet.

01What is happening

Cold roof, warm shop, and the customer sees the drip.

A retail unit is heated for people all day, with doors that open every minute and a stock room that is barely heated at all. The roof sheet or the soffit above is the coldest surface in the building. On a cold morning water forms on it and lands on stock, ceilings and the shop floor. In a shopping centre it lands on the units below.

Inside a retail warehouse before opening: the underside of a profiled steel roof misted with condensation above high shelving of boxed stock, a stained ceiling tile and a drip mark on the floor of the aisle.
The roofBelow the dew point
  • Doors that never stop. Moist outside air comes in with every customer and finds the cold sheet above.
  • Stock rooms run cold. Lightly heated back-of-house is where the drips start first.
  • Soffits above units. In a centre or under a car park, the cold surface is the concrete over the shop.

It is not a roof defect. Repairing the roof will not stop it.

It is not solved by heating harder. Warmer air holds more moisture and finds the same cold surface.

It is not always condensation. Water at a lap, a fixing or a rooflight during rain is ingress, repaired first, by someone else.

02Recent projects

A live shopping centre, sprayed overhead with the units trading.

HOLVEM's own record from a regional shopping centre: 3800 m² of soffit above trading units, closed-cell foam at 140 mm in three passes, condensation above the units eliminated and the centre trading throughout. Labelled as it should be: Project record.

A HOLVEM installer in full protective equipment spraying closed-cell foam onto an overhead soffit above a shopping centre unit, polythene masking hung below.
Project recordShopping centre soffit
3800 m² live retail soffitsClosed cell, 140 mm, condensation eliminated.

Project record

Regional shopping centre · soffit

Area
3800 m² multi-zone soffits
System
Closed cell · 140 mm · 3 passes
Delivery
Live retail, phased, full QA pack

Condensation above trading units eliminated, engineered to 0.18 W/m²K, with the centre trading throughout.

03What is applied

Closed-cell foam to the roof underside or the soffit, following the shape.

On a retail shed the existing sheet stays as the weather line and the layer is applied from below, closing the side laps and wrapping the purlins. On a centre or an undercroft the layer goes onto the concrete soffit above the unit. Either way it is one continuous bonded layer with nowhere for condensation to start.

Schematic / not to scaleKeyed 1 to 5 below

Inside a retail unit after the work, before the shelving is restocked: the profiled steel roof and purlins sprayed from beneath in a continuous cream closed-cell layer, the lighting rig and rooflights left clear.
AppliedAbove the shop floor
The layer stops cleanly at rooflights, lighting and services, which are masked and left clear.
1 / Existing roof or soffit

Profiled sheet or concrete. It stays, and we do not make it watertight.

2 / Prepared face

Dust, loose coating and contamination removed. Adhesion is decided here.

3 / Closed-cell layer, in passes

Follows the profile or the soffit. λ 0.027 W/mK is the NexSeal LE product figure.

4 / Purlins, beams and fixings

Encapsulated by the application, and still a thermal bridge in the calculation.

5 / Coating, where specified

B-s2,d0 belongs to the coated NexSeal LE and DC315 system, as tested. Uncoated, that classification does not carry.

04Working around the building

Out of hours, one unit at a time, open again in the morning.

Trading does not stop. The work is phased by unit or by zone, after close, with stock and fittings under the spray zone sheeted or moved, and the area cleaned and handed back before the doors open. A centre is treated the same way, one soffit zone at a time.

  1. 1 / 3

    After close, before open

    Nights and closed days where the unit allows. The programme is agreed with the store manager and, in a centre, with centre management.

  2. 2 / 3

    Protect the stock

    Shelving, tills, fittings and stock under the spray zone are sheeted or moved. Containment keeps overspray inside the zone.

  3. 3 / 3

    Hand back clean

    Masking down, floor cleaned, zone returned before trading. Ventilation during cure and re-entry time are set out in the method statement.

05Enverge NexSeal LE

The material we spray, and why it matters.

Enverge NexSeal LE is a two component closed cell polyurethane, spray applied directly onto the prepared substrate. As it cures, it expands and sets into one rigid, continuous layer, bonding into corrugations, laps, fixings and awkward junctions without being cut, jointed or mechanically fixed.

That matters because most insulation problems start at the gaps.

Board systems can leave voids at ribs, laps and junctions, and every gap is a potential cold bridge where warm internal air meets a cold surface and condensation forms, hidden behind the insulation. NexSeal LE is applied as one continuous bonded layer, so there is nowhere for that to start: a sealed, stable building envelope that controls condensation, reduces heat loss and protects the structure underneath.

0.027 W/mKThermal conductivity · aged · BS EN 14315-1
Class 1Surface spread of flame · BS 476-7 · uncoated
B-s2,d0Coated, as tested · BS EN 13501-1
25 yearsWorkmanship warranty, plus the manufacturer’s

HOLVEM also installs open-cell foam. It is a different product with its own data sheet, specified for different objectives: hybrid build-ups, sound absorption, or where the layer has to breathe. It is not what goes onto a cold sheet or a cold soffit. Open-cell system data · Closed-cell system data

HOLVEM spray rig van with Enverge NexSeal LE A and B component drums plumbed into the proportioner.
HOLVEM rigA and B on board
The HOLVEM rig · Enverge NexSeal LE A and B components on board. HOLVEM's own photograph.

06How we check

We check the moisture before we spray.

A shop's moisture load comes through the door with the customers. The condensation risk analysis runs with the trading pattern in it; the U-value calculation is done for this roof or soffit; the EPC position is checked with the assessor before anyone promises a band.

  1. 1 / 3

    Condensation risk analysis

    The roof or soffit build-up is checked against the temperature and humidity the unit actually runs at, to BS EN ISO 13788 and, where the case warrants it, a transient WUFI analysis. The depth that keeps the surface above the dew point comes out of this.

    How the analysis works
  2. 2 / 3

    U-value, with the bridges in it

    Where a figure has to be met, the calculation is done for this build-up to BS EN ISO 6946 with purlins or beams included. A contract-specified 0.18 W/m²K on live retail soffits needed 140 mm; that is a record, not a promise for your unit.

    U-values and Approved Document L
  3. 3 / 3

    EPC and MEES, honestly

    Insulating the roof usually improves the rating; by how much depends on the whole building, and the assessor holds that position. HOLVEM supplies the calculation and the evidence pack the assessor needs.

    EPC, MEES and compliance

07The objective sets the depth

Four objectives. Each one sets the depth.

What does the roof need to do? Pick one below and you will see the depth that does it, and just as plainly what it won’t do. Nothing is left to come out later: the survey confirms the right depth for your building.

Four depths, drawn to one scale and measured from the deck. The objective and the calculation set the thickness on your building.

Pick an objective above to see the depth that does it, and what it won’t do.

Thickness and objective

Want a figure for your building? It takes about a minute.Building, roof, reading, details. A real figure for your unit the same working day; nothing sent to anyone else.

Get my estimate

08Straight answers

Ask us the hard ones.

The questions retailers, landlords and centre managers actually ask on the call, answered the way the specialist answers them. A question we have not answered? Ask it on the call. No obligation.

Can we keep trading?
Yes. The work is phased out of hours, one unit or zone at a time, with stock and fittings under the spray zone sheeted or moved and the area cleaned before the doors open. A regional shopping centre traded throughout while 3800 m² of soffit above its units was sprayed.
Will it improve our EPC?
Insulating the roof or soffit usually improves the rating, and on a retail shed the roof is often the largest single element. How far it moves the band depends on the whole building and is the assessor's position, not ours. HOLVEM supplies the U-value calculation and the evidence pack the assessor needs. EPC, MEES and compliance.
How much does retail unit insulation cost?
It depends on the depth, and the depth depends on the objective. Condensation control starts at 25 mm and retaining heat at 50 mm; the rate falls as the area rises. A U-value target above 75 mm and a coated Euroclass B system are both priced per project, because the target sets the depth and the coating sits on top of the foam.
Does the finished surface look acceptable in a shop?
The cured layer is a pale, continuous, rigid surface. Where the roof is exposed to customers the specification can include a finish coat, with the colour and finish agreed for your unit. Where there is a suspended ceiling, the layer sits above it and nobody sees it.
Who signs off the fire performance?
The fire strategy for the building decides whether a reaction-to-fire classification is required. Where it is, the coated NexSeal LE and DC315 system achieves B-s2,d0 to BS EN 13501-1 in the build-up tested; uncoated, that classification does not carry. HOLVEM answers what the system achieves; the strategy answers what the unit needs.

The next step

Your building.
Your brief.
A specialist.

If you already know the thickness or U-value you need, we price to it and confirm it is right; if not, we work it out with you. The estimator at the top takes about a minute and asks for nothing until the reading is on screen. “Not sure” is a useful starting point.

Or call . Enquiries received before 3pm on a working day are contacted the same day. After 3pm, the next working day. A commitment to contact, not a quotation, a survey or a price.

Rather write it all down first? Start a project brief · about five minutes, photographs welcome.